This is 1800Awnings' manufacturer guide specification for architectural extruded aluminum canopies, written to CSI MasterFormat Section 10 73 16. Text in [brackets] is an option or value for the specifier. Structural design is delegated per project to a licensed professional engineer; load capacities are determined per project, not stated here. See also our architectural canopy systems and resources for architects.
PART 1 - GENERAL
1.1 SUMMARY
- Section includes: Shop-fabricated, building-mounted architectural canopies of extruded aluminum, including framing, fascia, gutter, roof panels, support arms, hanger rods, posts, brackets, anchorage, and accessories.
- Canopy system types:
- [Integrated gutter-fascia canopy (G-Gutter profile), fascia height [6] [8] [10] [12] inches.]
- [C-Channel perimeter canopy with integrated drainage.]
- [Cantilevered canopy with concealed wall brackets and no front posts or tie rods.]
- [Open tube canopy.]
- [Standing seam canopy with Galvalume roof panels over aluminum framing, [open] [closed] ends.]
- Related requirements:
- Section 05 50 00 "Metal Fabrications" for wall backing and embedded supports provided by others.
- Section 07 62 00 "Sheet Metal Flashing and Trim" for flashing at building wall beyond canopy scope.
- Section 09 96 00 "High-Performance Coatings" where architectural-grade coating requirements are coordinated.
- Section 10 71 13 "Exterior Sun Control Devices" for louvered sunshades.
Specifier Note: Use Section 10 73 26 "Walkway Coverings" for freestanding covered walkway runs. Louvered sunshade canopies are specified under 10 71 13.
1.2 REFERENCES
- American Society of Civil Engineers (ASCE): ASCE 7, Minimum Design Loads and Associated Criteria for Buildings and Other Structures, edition adopted by the Authority Having Jurisdiction.
- The Aluminum Association: Aluminum Design Manual.
- American Architectural Manufacturers Association (AAMA): AAMA 2603, 2604, and 2605, Voluntary Specifications, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels.
- Building code: [Florida Building Code] [International Building Code] as adopted by the Authority Having Jurisdiction.
1.3 DELEGATED-DESIGN SERVICES
- Delegated design: Engage a qualified professional engineer licensed in the project state to design canopy framing, connections, and anchorage to the building structure.
- Design criteria:
- Wind: ASCE 7 ultimate design wind speed [___] mph, Exposure Category [B] [C] [D], Risk Category [I] [II] [III] [IV].
- Snow load: [___] psf ground snow load, including drift where applicable. [Not applicable.]
- Live load: As required by the building code for canopies of this type.
- Substrate: Anchorage designed for the actual wall construction: [CMU] [cast-in-place concrete] [concrete tilt-wall] [steel stud with backing] [structural steel].
Specifier Note: Brick veneer and unbacked light-gauge stud framing cannot resist the moment imposed by a cantilevered canopy. Coordinate backing or select a hanger-rod or post-supported configuration.
1.4 ACTION SUBMITTALS
- Product data: Manufacturer's product data and cut sheets for each canopy system.
- Shop drawings: Plans, elevations, sections, and details showing dimensions, profiles, support configuration, drainage path and discharge point, anchorage, and connections to the building.
- Delegated-design submittal: Structural calculations signed and sealed by the qualified professional engineer responsible for their preparation.
- Samples: Finish samples for each color and finish selected, including woodgrain finishes where specified.
1.5 INFORMATIONAL SUBMITTALS
- Anchorage details and installation instructions.
- Sample warranty.
1.6 QUALITY ASSURANCE
- Manufacturer qualifications: A firm that fabricates, welds, and finishes canopy systems in its own facility, with not less than [10] years of experience manufacturing extruded aluminum canopies.
Specifier Note: 1800Awnings.com has manufactured aluminum awning and canopy systems in Tampa, Florida since 1987.
- Single source: Obtain canopy framing, fascia, finish, and support components from a single manufacturer.
1.7 DELIVERY, STORAGE, AND HANDLING
- Deliver canopies [fully welded and crated] [as knock-down kits with pre-cut, pre-drilled components and stainless steel hardware].
- Inspect shipments at delivery. Note damage on the carrier's delivery receipt and report to the manufacturer within 24 hours.
- Store off the ground, protected from damage, in manufacturer's packaging until installation.
1.8 WARRANTY
- Manufacturer's finish warranty: Five (5) years against defects in the powder-coated finish.
- Manufacturer's workmanship warranty: Two (2) years against defects in fabrication and workmanship.
- Exclusions: Damage from severe weather, natural disasters, accidents, or improper installation.
PART 2 - PRODUCTS
2.1 MANUFACTURER
- Basis of design: 1800Awnings.com, 4608 N Hale Ave, Tampa, FL 33614. Tel. (800) 296-4647. Email sales@1800awnings.com. Web www.1800awnings.com.
- Substitutions: [Not permitted.] [Under provisions of Division 01.]
2.2 PERFORMANCE REQUIREMENTS
- Structural performance: Canopy assemblies and anchorage shall withstand the design loads in Article 1.3 without failure, permanent deformation, or detachment.
- Drainage: Canopy shall collect and discharge rainwater to the location shown on the drawings. [Discharge onto public walkways and accessible routes is not permitted.]
2.3 MATERIALS
- Aluminum: Extruded aluminum profiles, alloy and temper as required by the delegated structural design. Roll-formed sheet framing is not acceptable.
- Standing seam roof panels: Interlocking Galvalume (aluminum-zinc alloy-coated steel) panels. [Standing seam systems only.]
- Fasteners: Stainless steel.
- Anchors: Type, size, and embedment as indicated on the sealed delegated-design drawings for the substrate encountered.
2.4 CANOPY SYSTEMS
- Integrated gutter-fascia canopy (basis of design: G-Gutter Series):
- Fascia: Extruded aluminum gutter-fascia, [6] [8] [10] [12] inches high, with gutter integrated in the leading edge.
- Drainage: [Leading-edge gutter to downspout] [Internal scupper and concealed downspout].
- Support: [Cantilevered wall brackets] [Hanger rods to wall above] [Posts].
- C-Channel canopy (basis of design: C-Channel Series):
- Perimeter: Welded extruded aluminum C-channel with integrated drainage.
- Fascia height: [6] [8] [10] [12] inches.
- Support: [Cantilevered wall brackets] [Posts].
- Cantilevered canopy (basis of design: Cantilever Series):
- Supported entirely from the wall on concealed structural brackets, with no front posts or tie rods.
- Open tube canopy (basis of design: Open Tube Series):
- Open extruded aluminum tube framing with hanger-rod support to the wall above.
- Standing seam canopy (basis of design: [S-Series, closed ends] [O-Series, open ends]):
- Galvalume standing seam panels over powder-coated extruded aluminum framing.
- Integrated flashing at all roof-to-wall connections.
- Configuration: [Flat] [Pitched].
- Dimensions: Width, projection, and fascia height as indicated on the drawings. Canopies are custom-fabricated to project dimensions.
2.5 FABRICATION
- Fabricate canopies in the manufacturer's facility to dimensions verified from the shop drawings, to a tolerance of plus or minus 1/16 inch.
- Assembly: [Fully welded, factory-assembled units] [Knock-down kits with pre-cut, pre-drilled components for field assembly].
Specifier Note: Welded, crated units install fastest and are recommended for commercial work. Knock-down kits suit restricted site access, upper-floor placement, or freight constraints.
2.6 FINISHES
- Powder coat: Apply to 100 percent of exposed and concealed surfaces, including top face, underside, fascia returns, framing, and mounting brackets.
- Performance: [Manufacturer's standard powder coat] [AAMA 2604] [AAMA 2605].
- Color: [RAL ____] [Match Architect's sample] [Match owner's brand standard] [As selected by Architect from manufacturer's full range].
- Woodgrain finish: [Where indicated, sublimated woodgrain finish applied over powder coat, pattern [cedar] [mahogany] [walnut] [as selected by Architect].]
- Graphics: [Lettering and graphics applied to fascia as indicated.] [Not required.]
PART 3 - EXECUTION
3.1 EXAMINATION
- Verify that wall construction, backing, and embedded supports are in place and conform to the anchorage requirements of the delegated-design drawings before installation.
- Verify field dimensions and elevations before fabrication.
3.2 INSTALLATION
- Install canopies in accordance with the approved shop drawings, the sealed delegated-design drawings, and the manufacturer's installation instructions.
- Set canopies level, plumb, and true to line, with gutters sloped to drain to the discharge point indicated.
- Install flashing and sealant at wall connections to prevent water intrusion.
- Connect downspouts and route discharge as indicated.
3.3 ADJUSTING AND CLEANING
- Touch up minor finish damage with touch-up material matching the factory finish, as recommended by the manufacturer. Replace components with damage that cannot be concealed by touch-up.
- Clean exposed surfaces in accordance with the manufacturer's recommendations. Do not use abrasive cleaners.
END OF SECTION 10 73 16